top of page

Victron Phoenix Inverter 12/1600 120V VE.Direct NEMA 5-15R

$425.00Price
Quantity

<p><strong>Phoenix Inverter 12/1600 120V VE.Direct NEMA 5-15R</strong></p><p id="isPasted">Inverters allow users to power domestic equipment, requiring 230V/120V AC, using 'leisure' or 'automotive' batteries rated at 12V, 24V, or 48V DC.</p><p>VE.Direct Communication Port</p><p><strong>The VE.Direct port can be connected to:</strong></p><ul><li>A computer (VE.Direct to USB interface cable needed)</li><li>Apple and Android smartphones, tablets, MacBooks, and other devices</li><li>(VE.Direct Bluetooth Smart dongle needed)</li></ul><p><strong>Fully Configurable:</strong></p><ul><li>Low battery voltage alarm trip and reset levels</li><li>Low battery voltage cut-off and restart levels</li><li>Dynamic cut-off: load-dependent cut-off level</li><li>Output voltage 210 - 245V</li><li>Frequency 50 Hz or 60 Hz</li><li>ECO mode on/off and ECO mode sense level</li></ul><p><strong>Monitoring:</strong></p><p>In and output voltage, % load, and alarms</p><p><strong>Proven Reliability</strong></p><p>The full bridge plus toroidal transformer topology has proven its reliability over many years.</p><p>The inverters are short-circuit proof and protected against overheating, whether due to overload or high ambient temperature.</p><p><strong>High Start-Up Power</strong></p><p>Needed to start loads such as power converters for LED lamps, halogen lamps, or electric tools.</p><p><strong>ECO Mode</strong></p><p>When in ECO mode, the inverter will switch to standby when the load decreases below a preset value (min load: 15W). Once on standby, the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.</p><p><strong>Remote On/Off</strong></p><p>A remote on/off switch can be connected to a two-pole connector, or between the battery plus and the left-hand contact of the two-pole connector.</p><p><strong>LED Diagnosis</strong></p><p>To Transfer the Load to Another AC Source: The Automatic Transfer Switch</p><p>For Victron’s low-power inverters, they recommend the Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption. </p><p><strong>Inverter Specifications:</strong></p><ul><li>Cont. Power at 25 degrees C: (1) 250VA </li><li>Cont. Power at 25 degrees C / 40 degrees C: 200 / 175W </li><li>Peak Power: 400W </li><li>Output AC Voltage / Frequency (adjustable): 230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1%</li><li>Input Voltage Range: 9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V</li><li>DC Low Shut Down (adjustable): 9,3 / 18,6 / 37,2V</li><li>Dynamic (load dependent) DC Low Shut Down (fully configurable): Dynamic cut-off, see https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff</li><li>DC Low Restart & Alarm (adjustable): 10,9 / 21,8 / 43,6V</li><li>Battery Charged Detect (adjustable): 14,0 / 28,0 / 56,0V</li><li>Max. Efficiency: 87 / 88 / 88% </li><li>Zero-Load Power: 4,2 / 5,2 / 7,9W </li><li>Default Zero-Load Power in ECO Mode (default retry interval: 2,5 s, adjustable): 0,8 / 1,3 / 2,5W </li><li>ECO Mode Stop & Start Power Setting: Adjustable</li><li>Protection (2): a - f</li><li>Operating Temperature Range -40 to +65 degrees C (fan-assisted cooling) </li></ul><p><strong>Enclosure Specifications:</strong></p><ul><li>Material & Color: Steel chassis and plastic cover (blue Ral 5012)</li><li>Battery-Connection: Screw terminals</li><li>Maximum Cable Cross-Section: 10mm² / AWG8 </li><li>Standard AC Outlets: 120V: NEMA 5-15R</li><li>Protection Category: IP 21</li><li>Weight: 2,4kg / 5.3 lbs </li><li>Dimensions (H x W x D, mm); (H x W x D, inch): 86 x 165 x 260; 3.4 x 6.5 x 10.2</li></ul><p><strong>Accessories:</strong></p><ul><li>Remote On-off: Yes</li><li>Automatic Transfer Switch: Filax</li></ul><p><strong>Standards:</strong></p><ul><li>Safety: EN-IEC 60335-1 / EN-IEC 62109-1 / UL 458 (3)</li><li>EMC: EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3</li><li>Automotive Directive ECE R10-4: 1) Nonlinear load, crest factor 3:1; 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) DC ripple too high</li></ul><strong>Please contact your dealer for any returns, repairs or support issues related to this product.</strong> <!--- cis2:mm5sl5hm --->

    bottom of page